Comparative data for plastic films - Berkem Plast

Go to content
DIFFERENCES OF POLYESTER FILM
Comparative data for plastic films
You can examine the details of polyester films that are different from other plastic films on this page.

PRODUCTION DIFFERENCES

Units
BOPET
BOPP
PVC
Production
./.
Extrusion
Biaxial
Perdah Merdanesi
Tension
./.BiaxialBiaxialNo polymer chain orientation/ or transverse orientation to the production line
Thickness
µm1 - 500
4 - 80
Transverse orientation:  30 to 100
No orientation:  100 to 600
MECHANICAL DIFFERENCES

Orientation
Units
BOPET
BOPP
PVC
Tensile Strength
MD*
TD*
N/mm ²
200
200
150
250
50
50
Breaking Elongation
MD*
TD*
%
100
100
150
50
10
10
Tension required for % 5 elongation
MD*
TD*
N/mm ²
100
100
./.
./.
./.
./.
Testing Standards


ISO 527-1-2
ISO 527-1-2
ISO 527-1-2
Testing Condition


23°C, 50%
23°C, 50%
23°C, 50%
Young’s Modulus
MD*
TD*
N/mm ²
4500
4500
2500
4500
./.
./.
ELECTRICAL SPECS

BOPET
BOPP
PVC
Dielectric Constant
3,3
2,2
4,2
Dielectric Dissipation Factor
0,002
0,0002
0,02
Test Standard
DIN 40634
DIN 40634
DIN 40634
Test Conditions
23°C, 50 Hz
23°C, 50 Hz
23°C, 50 Hz
DIMENSIONAL STABILITY

Units
BOPET
BOPP
PVC
Shrinkage (MD*)
%
1 - 3
(150°C)
3 - 5
(120°C)
4 - 7
(140°C)
Shrinkage (TD*)
%
0 - 2
(150°C)
0 - 2
(120°C)
-0,5 - 2
(140°C)
Test Standards
./.
DIN 40634
DIN 40634
DIN 40634
Test Conditions
./.150°C, 15 min
120°C, 15 min140°C, 15 min
TYPICAL THERMAL VALUES

Units
BOPET
BOPP
PVC
Melting Point
°C
260
166
200 - 220
Glass Transition Temperature
°C
70
-20
80
Test Standards
./.Differential Scanning Calorimetre
Differential Scanning Calorimetre
Differential Scanning Calorimetre
Test Conditions
./.3K/min
3K/min
3K/min
BARRIER VALUES

Units
BOPET
BOPP
PVC
Oxygen
cm 3 /m² x d x bar
17
250
40
Water Vapour
g/m² x d
20,25
3
Testing Standards for Oxygen
./.
DIN 53380
DIN 53380
DIN 53380
Testing Standards for Water Vapour
./.
DIN 53122
DIN 53122
DIN 53122
Test Conditions
./.23°C
23°C
23°C
DİĞER ÖZELLİKLER

Units
BOPET
BOPP
PVC
Density
g/cm³
1,4
0,9
1,4
Water Absorbation
%
0,5
< 0,1
0,5
Test Standards
./.
DIN 53472 and ASTM D 570
DIN 53472 and   ASTM D 570
DIN 53472 and ASTM D 570
Test Conditions
./.4 days in 23°C water
4 days in 23°C water
4 days in 23°C water
MD*: Machine direction
TD*: Transverse direction
For more information, please have a look at the section about “polyester film production process”
Note: The property values provided in this text are similar to the property values of our products. However, the purpose of this text is to differentiate the different types of products. For detailed information about our products, please contact us.

© 1994-2022 Berkem Plast Industry and Trade Limited Company All Rights Reserved.
Berkem
BERKEM PLAST
Yenidogan Mh. Akin Cd. No:39,
PK: 34791 Sancaktepe, Istanbul / Turkey
P: +90 216 429 99 91
F: +90 216 429 99 92
E: info@berkemplast.com
Back to content